Iwe have been customers of TOTAL COMFORT SINCE WE MOVED TO FL. 19 YEARS AGO. WE HAD WAYNE ALL THOSE YEARS AND NOW TIM. TIM IS EXCELLENT. ON TIME,-----COURTEOUS. LOOK FORWARD TO HIS NEXT VISIT. WANT ONLY TIM TO COME AGAIN.
Total Comfort is very lucky to have Tim Richards!! You will not find a more professional, proficient, knowledgeable, thorough, or friendly technician anywhere! We always request him so don't ever let him go! :-)
I have been quite happy with Total Comfort from the office staff to the technician. I have recommended Total Comfort to a family member and they too are also very pleased. Won't go anywhere else!!!!
as stated above the service was wonderful.
Always a great job. Pleasure to do business with.
Tim is a personnable person , and did a very through service job.
Service is always great with you guys. Would recommend your company to anybody.
Company representative was courteous and explained everything as he went along. We were very pleased with the service.
Air Conditioning Service: FOUND CONDENSER OFF ON ARRIVAL. CHECKED TO FIND BAD CAPACITOR. REPLACED CAPACITOR AND FLUSHED DRAIN. SYSTEM IS OPERATING PROPERLY AT THIS TIME.
Air Conditioning Service: CHECKED TO FIND FAN DOES RUN PROPERLY OFF OF THE PCB AND METAL PLATE TOUCHING BOTTOM OF CONTACTOR. REMOVED PLATE AND REPLACED TERMINALS THAT WERE BURNT. RESET BREAKER AND
Air Conditioning Service: 2ND CHECK ON ESA MAINTENANCE AND RENEWAL
Air Conditioning Service: 2ND CHECK ON ESA MAINTENANCE CONTRACT THIS SYSTEM IS OPERATING CORRECTLY
Air Conditioning Service: CHANGED OIL AND OIL FILTER-CHECKED OPERATION AND TRANSFER-TRANSFERRING AND OPERATING PROPERLY-FUEL AT 80%
Air Conditioning Service: REPLACED LISTED PARTS TO FIND OTHER SENSOR WAS NO GOOD AS WELL-OTHER SENSOR ON ORDER
Air Conditioning Service: FOUND BLOWER NOT RUNNING IN COOL MODE-24V FROM G TO C-MOTOR AND BLOWER MOTOR HARNESS NEED REPLACED
Air Conditioning Service: FOUND DRAIN LINE CLEAR, BELLY OF AIR HANDLER IS SWEATING DRIPPING INTO SECONDARY PAN, SECONDARY PAN IS VERY RUSTED AND IS LEAKING THRU ONTO 2X4S THAT SUSPEND IT. 26"X48"
Air Conditioning Service: RECALIBRATED THERMOSTAT, ALSO ADJUSTED SETTING IN THERMOSTAT CONFIGURATION TO ROOM TEMPERATURE RATHER THAN THE REMOTE SENSOR. ANDREA IS AWARE AND WE WILL EVALUATE
Air Conditioning Service: EVAPORATOR COIL IS 75% FROZE-UP, 2" THICK, WILL COME BACK WHEN ICE IS GONE, SUSPECT REFRIGERANT LEAK,
Air Conditioning Service: FOOT MOUNT 30 AMP. SQUARE D BREAKER HAS FAILED, NEED NEW BREAKER
Air Conditioning Service: COMPLETED MAINTENANCE. SYSTEM IS WORKING PROPERLY AT THIS TIME
Air Conditioning Service: SYSTEM IS OPERATING PROPERLY AT THIS TIME
Air Conditioning Service: FOUND RETURN GRILLE VANE BUZZING CAUSING NOISE.FOAM TAPPED VANES TO HELP ELIMINATE NOISE.CHECKED OVER SYSTEM BLOWER HOUSING AND BEARINGS IN MOTOR.SYSTEM IS COOLING PROPERLY
Plumbing: INSTALL NEW KIT FAUCET WITH NEW SPRAYER AND SUPPLY LINES